Our Services

What We Do

Air Conditioning

Specialising in all types of reverse cycle split systems including, hi-wall mounted, floor standing, multi head, ceiling concealed and under ceiling cassettes as well as and fully ducted systems.

Air conditioning service Icon

Refrigeration

Installation, Repair and Maintenance of all domestic and commercial sized coolrooms and freezer rooms. We also carry out repairs and maintenance for all shop and commercial size fridges and freezers.

Refrigeration Icon

Maintenance & Service

Troubleshooting, fault finding, part replacement, leak detection, cleaning and much more for all refrigeration and air-conditioning, including evaporative coolers.

Maintenance & Service Icon

Air Conditioning

Specialising in all types of reverse cycle split systems including, hi-wall mounted, floor standing, multi head, ceiling concealed and under ceiling cassettes as well as and fully ducted systems.

Air conditioning service Icon

Air Conditioning

Airconditioning Icon

Refrigerated Reverse Cycle Air Conditioning has become progressively more popular, because unlike Evaporative Coolers, they can provide year round comfort – Heating in Winter & Cooling in summer.

Reverse cycle systems work well in humid conditions, drawing the humidity out of your home. The following examples of installations are just some of the solutions we provide. Please contact us for any other ideas.

Wall Mount Split Systems

Rowdy Cool Air - Air Conditioning Service

Ceiling Cassettes

Rowdy Cool Air - Air Conditioning Service

Ducted Reverse Cycle

Rowdy Cool Air - Air Conditioning Service

Wall Mount Split Systems

Wall mount split systems efficiently cool or heat a single room and are installed with the indoor unit located high up on an inside wall. The condenser unit can be installed outside on the ground or on a wall or roof bracket. Interconnecting pipes and cable join the two together and are concealed in pipe cover.

The simplest way to install these systems is back to back where, the Indoor Fan Unit is installed on the Inside of the Perimeter Wall, and the Installer cuts the hole in the wall and runs the Pipes / Interconnect Wiring to the Outdoor Condensing Unit located on the Ground (single Storey) directly behind the same wall.

Wall Mount Split Systems

Wall mount split systems efficiently cool or heat a single room and are installed with the indoor unit located high up on an inside wall. The condenser unit can be installed outside on the ground or on a wall or roof bracket. Interconnecting pipes and cable join the two together and are concealed in pipe cover.

The simplest way to install these systems is back to back where, the Indoor Fan Unit is installed on the Inside of the Perimeter Wall, and the Installer cuts the hole in the wall and runs the Pipes / Interconnect Wiring to the Outdoor Condensing Unit located on the Ground (single Storey) directly behind the same wall.

What’s Included in our Wall Mount Install!

  • 15 metres of Power Cable to Main Electrical Board
  • 6 metres of Interconnect Wiring
  • 5 metres of Refrigerant Piping
  • 5 metres of Condensation Drain
  • All Refrigeration Labour
  • 4 metres of Duct Cover to conceal Pipe, Cable & Drain
  • 1 Wall Entry and 2 x 90 deg Elbows for Duct Cover
  • 1 x Waterproof Electrical Isolator near Outdoor Unit
  • 1 x Mounting Block or 100kg Wall Bracket for Outdoor Unit
  • Compliance Certificate

Ceiling Cassettes

Cassette Units are extremely discreet with only the grille showing in the ceiling. They allow air to be delivered in four directions for even temperature distribution. Cassette units are easy to clean and maintain. Outdoor units can be positioned where you prefer.

Ceiling Cassettes

Cassette Units are extremely discreet with only the grille showing in the ceiling. They allow air to be delivered in four directions for even temperature distribution. Cassette units are easy to clean and maintain. Outdoor units can be positioned where you prefer.

What’s Included in our Ceiling Cassette Install!

  • 15 metres of Power Cable to Main Electrical Board
  • 16 metres of Interconnect Wiring
  • 15 metres of Refrigerant Piping
  • 10 metres of Condensation Drain
  • All Refrigeration Labour
  • 4 metres of Duct Cover to conceal Pipe, Cable; Drain
  • 1 Wall Entry and 2 x 90 deg Elbows for Duct Cover
  • 1 x Waterproof Electrical Isolator near Outdoor Unit
  • 1 x Mounting Block or 100kg Wall Bracket for Outdoor Unit
  • Compliance Certificate

Ducted Reverse Cycle

These systems are concealed in your ceiling, offering quiet operation and control of multiple rooms or the entire house from one control.

Ducted Reverse Cycle Air Conditioning is generally zoned throughout your home to suit your lifestyle, and to reduce the running costs and possibly the initial outlay. Your System size is dependent on the maximum capacity you will require to cool or heat the area’s you determine will be in use simultaneously i.e. the more Zones you wish to use at once, the bigger the capacity required to run them. It is imperative that your Air Conditioning Unit is sized correctly for its intended use, so that it runs efficiently & therefore economically

Ducted Refrigerated Reverse Cycle

These systems are concealed in your ceiling, offering quiet operation and control of multiple rooms or the entire house from one control.

Ducted Reverse Cycle Air Conditioning is generally zoned throughout your home to suit your lifestyle, and to reduce the running costs and possibly the initial outlay. Your System size is dependent on the maximum capacity you will require to cool or heat the area’s you determine will be in use simultaneously i.e. the more Zones you wish to use at once, the bigger the capacity required to run them. It is imperative that your Air Conditioning Unit is sized correctly for its intended use, so that it runs efficiently & therefore economically

What’s Included in our Ducted Reverse Cycle Install!

  • 15 metres of Power Cable to Main Electrical Board
  • 16 metres of Interconnect Wiring
  • 15 metres of Refrigerant Piping
  • 10 metres of Condensation Drain
  • All Refrigeration Labour
  • 4 metres of Duct Cover to conceal Pipe, Cable; Drain
  • 1 Wall Entry and 2 x 90 deg Elbows for Duct Cover
  • 1 x Waterproof Electrical Isolator near Outdoor Unit
  • 1 x Mounting Block or 100kg Wall Bracket for Outdoor Unit
  • Compliance Certificate

Installation Extras

Some extra things may be required for your installation and we will be sure to let you know when we quote. An example of these are:

❄   Extra refrigeration piping & interconnect wiring, drain and duct cover between indoor & outdoor units sold as a bundle in 1m increments. This is required for non-standard back to back installations.

❄  Stainless steel 100kg wall brackets. Required if you wish for the outdoor condenser to be mounted on your perimeter wall.

❄  Roof mounts or brackets. These are required if you wish to have your condenser unit located on your roof.

❄  Extra power cable to the meter box.

Refrigeration

Installation, Repair and Maintenance of all domestic and commercial sized coolrooms and freezer rooms. We also carry out repairs and maintenance for all shop and commercial size fridges and freezers.

Refrigeration Icon

Refrigeration

Refrigeration Icon

If you have built a coolroom or freezer room, we can supply and install the refrigeration aspect for you. From ‘drop in’ small package units to ‘standard’ evaporator and condenser systems.

Drop in units – These units are an all in one package. They come complete with the evaporator coil mounted directly underneath the condensing unit, piped and electrically connected ready to plug in and go. Installation involves cutting a hole in the top of your room where you would like your evaporator to be placed. Once cut, the evaporator and its fans drop straight down into the room with the compressor and condenser sitting directly above. This is a quick and easy installation option to refrigerate your small coolroom.

Standard systems – These units come with a separate evaporator coil with fans and a condenser with compressor. You can hang the evaporator wherever needed inside the room, then the interconnecting copper pipe is installed between this and the condenser. This is a great option as the condenser can be located anywhere you desire. These style systems are good ro any size coolroom.

Rowdycool air provides obligation free quotations on all installations.

Maintenance & Service

Troubleshooting, fault finding, part replacement, leak detection, cleaning and much more for all refrigeration and air-conditioning, including evaporative coolers.

Maintenance & Service Icon

Maintenance & Service

Air Conditioning Service Icon

We recommend routine servicing of your system to ensure that your system is working as it should be and to keep on top of any minor problems which will aid in prevention of more serious, costly issues progressing in the future.

If you have noticed that your system isn’t cooling efficiently or you just haven’t used it since last summer, it might be time for a service.

What’s Included in our Standard Service!

  • Troubleshooting
  • Check all remote control settings
  • Clean Filters and fascia’s
  • Clean Outdoor Condensers
  • Check Refrigerant Levels and pressures
  • Check air on/air off temperatures
  • Complete an overall operational and performance analysis
Should there be a fault, we will report to you and quote on any repairs or part replacement that is required.
Rowdy Cool Air - Air Conditioning, Commercial Refrigeration

We pride ourselves on precise,
fast and effective service
at all times with second
to none workmanship and
communication.

Air Conditioning

Byford, Perth, Mandurah, Peel & Surrounds

Fully Qualified

Restricted Electrical Licence: EW161961
Refrigerant Handling Licence: L008995
Refrigerant Trading Authorisation: AU45177

Troy Davis
Ph: 0400 205 822

Find Us On Facebook